Blog

Water Quality Monitoring for Industrial Operations

By ClearWater Industries | Jul 15, 2026 |
Circulator pump and piping in an industrial water system

Industrial water systems operate under changing conditions that can affect equipment performance, treatment effectiveness, and regulatory compliance. Variations in source water, process demand, temperature, chemical feed, seasonal conditions, and system loading can alter water quality over time. Without consistent oversight, these changes may contribute to scale formation, corrosion, fouling, microbial growth, reduced heat transfer, and…

Read More

DAF Dissolved Air Flotation Systems Explained

By ClearWater Industries | Jul 15, 2026 |
Labeled DAF dissolved air flotation process diagram showing chemical conditioning, a flotation tank, fine air bubbles, surface sludge removal, clarified effluent, and a pressurized recycle stream.

Industrial facilities often generate wastewater containing oils, grease, suspended solids, food particles, biological material, and other contaminants that do not settle easily through gravity alone. When these materials remain in the wastewater stream, they can increase treatment demands, affect downstream equipment, and make discharge requirements more difficult to manage. A DAF dissolved air flotation system…

Read More

Cooling Tower Winterization Best Practices

By ClearWater Industries | Jul 13, 2026 |
Commercial cooling towers require seasonal winterization to help protect equipment from freezing temperatures, corrosion, and operational issues during cold weather.

As temperatures drop across the Northeast, preparing a cooling tower for extended periods of cold weather becomes an essential part of facility maintenance. For commercial buildings, schools, healthcare facilities, and other sites that rely on industrial cooling towers, proper cooling tower winterization helps protect equipment from freezing conditions, minimize corrosion, and support reliable operation when…

Read More

Cooling Tower Passivation After Cleaning or Startup

By ClearWater Industries | Jul 13, 2026 |
Commercial cooling tower equipment and piping supporting industrial water treatment and cooling system startup.

Whether following routine maintenance, a major cleaning, or the start up of a new cooling tower, protecting metal surfaces is an important part of long-term water treatment planning. Freshly cleaned or newly installed galvanized steel components are more vulnerable to early corrosion until they develop a stable protective film, making cooling tower passivation an essential…

Read More

Cooling Tower Basin Cleaning Procedures

By ClearWater Industries | Jul 9, 2026 |
Industrial cooling towers requiring routine cooling tower basin cleaning and preventive maintenance to support efficient operation

Industrial cooling tower basin cleaning is an essential maintenance practice that helps preserve water quality, support reliable equipment performance, and reduce the risk of operational issues caused by accumulated sediment, scale, and biological contaminants. As the cooling tower continuously circulates cooling water to remove heat from an HVAC system or industrial process, the cooling tower…

Read More

Boiler Scale Removal Techniques and Solutions for Commercial Boiler Systems

By ClearWater Industries | Jul 9, 2026 |
Commercial steam boiler system used in industrial boiler water treatment and boiler scale removal programs

Boiler scale removal is an important part of maintaining the reliability, efficiency, and longevity of any commercial boiler system. As boiler water is heated to produce steam or hot water, naturally occurring dissolved minerals can accumulate on heat transfer surfaces, forming boiler scale that restricts heat transfer and reduces overall boiler efficiency. Left untreated, scale…

Read More

Antiscalant Dosing Best Practices for RO Systems

By ClearWater Industries | Jul 6, 2026 |
Commercial reverse osmosis water treatment system with pretreatment equipment supporting antiscalant dosing.

Reverse osmosis (RO) systems play a critical role in producing high-quality water for commercial and industrial operations. Whether supporting manufacturing processes, food and beverage production, healthcare facilities, or large commercial buildings, these systems depend on clean, efficient membranes to maintain consistent performance. One of the most common challenges affecting RO systems is scale formation, which…

Read More

How Do You Use a Refractometer in Water Treatment?

By ClearWater Industries | Jul 6, 2026 |
Commercial water treatment equipment used in HVAC and glycol system maintenance.

Maintaining proper fluid concentration is an important part of commercial water treatment, particularly in closed-loop HVAC systems that rely on glycol for freeze protection and efficient heat transfer. Routine testing helps facility managers and water treatment professionals verify that these systems continue to perform as intended while reducing the risk of equipment damage, energy loss,…

Read More

How to Mix Coolant for Industrial and HVAC Systems the Right Way

By ClearWater Industries | Jul 2, 2026 |
Industrial HVAC equipment relies on properly mixed glycol coolant to provide freeze protection, efficient heat transfer, and long-term corrosion control.

Heating and cooling systems in commercial buildings depend on properly prepared coolant to maintain reliable operation throughout the year. Whether protecting a closed loop HVAC system during harsh Northeastern winters or maintaining consistent heat transfer in year-round applications, understanding how to mix coolant correctly helps reduce the risk of freezing, corrosion, equipment damage, and unnecessary…

Read More

Steam Quality Requirements for Industrial Processes and Reliable Performance

By ClearWater Industries | Jun 29, 2026 |
Commercial boiler system with insulated steam piping illustrating steam quality requirements for industrial processes.

Steam plays a vital role in industrial and commercial facilities, serving as a reliable source of thermal energy for heating, sterilization, manufacturing, and other critical processes. However, producing steam alone is not enough. Maintaining proper steam quality is equally important because the amount of moisture carried within the steam directly affects heat transfer efficiency, equipment…

Read More